Bug #33177

WebUI does not allow IP address as port for UPS

Added by Craig Shiels over 1 year ago. Updated about 1 year ago.

Status:
Closed
Priority:
No priority
Assignee:
Erin Clark
Category:
GUI (new)
Target version:
Seen in:
Severity:
Low Medium
Reason for Closing:
Duplicate Issue
Reason for Blocked:
Needs QA:
Yes
Needs Doc:
Yes
Needs Merging:
Yes
Needs Automation:
No
Support Suite Ticket:
n/a
Hardware Configuration:
ChangeLog Required:
No

Description

When selecting a UPS model that uses the "snmp-ups" driver, it is not appropriate to select any /dev file as being the port. Rather the "port" should be the IP address of the UPS.


Related issues

Related to FreeNAS - Bug #36173: Use ups.port_choices and ups.driver_choices to get ports and drivers for UPS in new UIDone

Associated revisions

Revision a6067c6b (diff)
Added by Erin Clark about 1 year ago

Allow user to enter in hostname or ip address for snmp-ups Ticket: #33177

History

#1 Updated by Dru Lavigne over 1 year ago

  • Category changed from OS to Middleware
  • Assignee changed from Release Council to William Grzybowski

#2 Updated by William Grzybowski over 1 year ago

  • Status changed from Unscreened to Screened

Can you workaround it by using the auxiliary parameters field?

#3 Updated by Craig Shiels over 1 year ago

Surprisingly the "port" field allows direct entry of text and the drop-down list can be ignored.
The community does need to be added as an additional.
There should also be a "Generic UPS RFC 1628 (snmp-us)" driver entry.

#4 Updated by Eric Loewenthal over 1 year ago

This has shown up on the forums a few times now. I could've sworn it had been added to the manual, but it doesn't seem to be the case.

Ideally, the GUI should change the field's label to "IP address" and not list devices.

#5 Updated by William Grzybowski over 1 year ago

  • Status changed from Screened to Unscreened
  • Assignee changed from William Grzybowski to Erin Clark

Erin, this seems like something to be handled by UI.

When a snmp driver is selected it should use a free form text field for driver and perhaps change label to IP/Hostname?

Let me know if there is any backend change required for this.

#6 Updated by Erin Clark over 1 year ago

  • Status changed from Unscreened to Screened

#7 Updated by Erin Clark over 1 year ago

  • Category changed from Middleware to GUI (new)

#8 Updated by Erin Clark about 1 year ago

  • Status changed from Screened to In Progress

I pushed the fix to this change here https://github.com/freenas/webui/pull/944, I do not have an SNMP enabled UPS to test this with but it looks like it does the right thing with saving the values.

#9 Updated by Erin Clark about 1 year ago

  • Assignee changed from Erin Clark to Vaibhav Chauhan

#10 Updated by Vaibhav Chauhan about 1 year ago

  • Assignee changed from Vaibhav Chauhan to Erin Clark

reviewed

#11 Updated by Dru Lavigne about 1 year ago

  • Related to Bug #36173: Use ups.port_choices and ups.driver_choices to get ports and drivers for UPS in new UI added

#12 Updated by Erin Clark about 1 year ago

  • Status changed from In Progress to Ready for Testing

#13 Updated by Dru Lavigne about 1 year ago

  • Status changed from Ready for Testing to Closed
  • Target version changed from Backlog to N/A
  • Reason for Closing set to Duplicate Issue