Project

General

Profile

Bug #78366

Use IEC units in Pool Manager of new UI

Added by Marco . over 2 years ago. Updated over 2 years ago.

Status:
Ready for Testing
Priority:
No priority
Assignee:
-
Category:
GUI (new)
Target version:
Seen in:
Severity:
New
Reason for Closing:
Reason for Blocked:
Needs QA:
Yes
Needs Doc:
No
Needs Merging:
No
Needs Automation:
No
Support Suite Ticket:
n/a
Hardware Configuration:
ChangeLog Required:
No

Description

Storage → Pools uses MB, GB and TB as units for the “Used” and “Available” columns. But the values are actually MiB, GiB and TiB. At the top the correct units are used: e.g.

HEALTHY(1.23 TiB Used / 4.56 TiB free)
.


Related issues

Has duplicate FreeNAS - Bug #79221: Base 2 (TiB) vs Base 10 (TB) confusion in Storage > PoolsClosed

Associated revisions

Revision 9796f1b9 (diff)
Added by Erin Clark over 2 years ago

Use iec for filesize pipe on entity-tree-table Ticket: #78366

Revision 3e367566 (diff)
Added by Erin Clark over 2 years ago

Use iec for filesize pipe on entity-tree-table Ticket: #78366 (cherry picked from commit 9796f1b99bc65f0903b108c0ebfd03ba9898bbdb)

History

#1 Updated by Dru Lavigne over 2 years ago

  • Assignee changed from Release Council to Anonymous
  • Target version changed from Backlog to 11.2-U4

#2 Updated by Dru Lavigne over 2 years ago

  • Status changed from Unscreened to In Progress

#3 Updated by Anonymous over 2 years ago

  • Status changed from In Progress to Unscreened

#4 Updated by Anonymous over 2 years ago

Master PR: https://github.com/freenas/webui/pull/2049
Stable PR: https://github.com/freenas/webui/pull/2048

Testing criteria: the units on the pool list should show the right ones (GiB, MiB, TiB, etc. instead of GB, MB, TB)

#5 Updated by Anonymous over 2 years ago

  • Status changed from Unscreened to In Progress

#6 Updated by Anonymous over 2 years ago

  • Has duplicate Bug #79221: Base 2 (TiB) vs Base 10 (TB) confusion in Storage > Pools added

#7 Updated by Anonymous over 2 years ago

  • Status changed from In Progress to Ready for Testing
  • Needs Merging changed from Yes to No

#8 Updated by Dru Lavigne over 2 years ago

  • Subject changed from Storage → Pools lists wrong units to Use IEC units in Pool Manager of new UI
  • Needs Doc changed from Yes to No

Also available in: Atom PDF